Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.
Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.
A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.
In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.
The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.
Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.
Efficient smoke protection curtain at high pressure levels and smoke temperatures up to 392 °F: The Stoebich Smoke Curtain T smoke protection curtain offers reliable protection against smoke penetration and satisfies the requirements defined for smoke protection closures acc. to DIN 18095-1. The system is approved up to a size of 23' x 14.8' – larger dimensions are technical feasible and can be realised on request. The Stoebich Smoke Curtain T can securely seal uneven floors by means of its elastic closure strip. In combination with other compensation measures and the use of fire protection fabric, additional protection goals can be realised. The curtain is closed without power using the force of gravity. In accordance with fire tests the Stoebich Smoke Curtain T smoke protection curtain (if the correct fabric is used) can withstand the effects of the fire for more than 90 minutes and also reduces the radiation heat.
Type
Smoke protection closure of textile construction or non-thermally insulating fire and smoke protection closure
Verification
CE identification pursuant to EN 16034:2014 in conjunction with EN 13241:2003+A2:2016
Closing direction
From top to bottom
Fire resistance
E 0 – EW 120 | tested in compliance with EN 1634-1:2014+A1:2018 | Classified according to EN 13501-2:2016
Smoke protection
Sa, S200 | tested in compliance with EN 1634-3:2005-01 | classified according to EN 13501-2:2016
Closing cycles
C, C1, C2 | tested in compliance with EN 12605:2000-08 and EN 12604:2017-12 | classified according to EN 13501-2:2016
Fire behaviour of the fabric
A2-s1, d0; B-s1, d0; E-d2 | tested in compliance with ISO 1716 and EN 13823 or ISO 11295-2 | classified according to EN 13501-1:2018
Environment conditions
Special environmental conditions are not taken into account (e.g. humidity > 80 %, ambient temperature < 5 °C and > 45 °C, wind loads etc.)
Visible surfaces
galvanized, RAL - smooth - silk gloss - standard shade, NCS - standard shade
Legendary system components: 1 = Smoke detector 2 = Housing 3 = Guide rail 4 = Control module 5 = Release device (Details of the electrical components are to be taken from the valid general type approval of the hold-open system.)
Legal dimensioning: Structure B = Clear shell construction height A = Clear shell construction width System AY = System height LH = Clear system height LB = Clear system width BJ = System width Housing BX = Depth BW = Height v = Offset between guide rail and housing Guide rail CD = Width CE = Depth BD = Offset left BE = Offset right
Structural system design (system drawing)
Fabric
System width
Unrolled length t
t (mm)
h (mm)
Stoebich Fire & Smoke Fabric P / E
< 32.8'
< 19.7'
13.78''
10.24''
Stoebich Fire & Smoke Fabric P / E
< 16.4'
< 14.8'
11.22''
7.87''
Stoebich Fire & Smoke Fabric P / E
< 11.5'
< 11.5'
7.48''
11.41''
Stoebich Fire & Smoke Fabric P / E
< 23'
< 16.4'
11.41''
14.17''
Stoebich Fire & Smoke Fabric E
< 23'
< 10.5'
13.78''
10.24''
Stoebich Fire & Smoke Fabric E
< 16.4'
< 8.2'
11.22''
7.87''
Stoebich Fire & Smoke Fabric E
< 11.5'
< 6.6'
7.48''
11.41''
Stoebich Fire & Smoke Fabric E
< 19.7'
< 9.8'
11.41''
14.17''
Housing
Ceiling mounting Typ A: BX = 285 mm, BW = 200 mm Typ B: BX = 350 mm, BW = 260 mm
Typ C: BX = 190 mm, BW = 290 mm Typ D: BX = 290 mm, BW = 360 mm Typ E: BX = 380 mm, BW = 420 mm
Wall mounting Typ B: BX = 350 mm, BW = 260 mm
Typ C: BX = 190 mm, BW = 290 mm Typ D: BX = 290 mm, BW = 360 mm Typ E: BX = 380 mm, BW = 420 mm
Wall mounting suspended ceiling with cover Typ B: BX = 350 mm, BW = 260 mm
Typ C: BX = 190 mm, BW = 290 mm Typ D: BX = 290 mm, BW = 360 mm Typ E: BX = 380 mm, BW = 420 mm
Guide rails
Type 1 (Wall mounting) CD = 104 mm CE = 74 mm BD/BE ≥ 0 mm v = 0 mm
Type 2 (Embrasure mounting) CD = 104 mm CE = 74 mm v = 0 mm
Type 2 (Niche mounting) CD = 104 mm CE = 74 mm v = 0 mm
CDN = 120 mm CEN = 100 mm
Note: Dotted line for the winding shaft receptacle (housing)